Cold and heat resistant cables -60~180℃ extreme temperatures cable

The highly flexible technology is specially designed to withstand extreme temperatures and is both flame retardant and resistant to temperatures as low as -60°C and complies with EN45545-2 fire rating HL3, TST-GH-S Cold and heat resistant cables has the characteristics of long-term high-temperature resistance, low-temperature resistance, radiation resistance, wear resistance, light weight, small size, and wide range. It is used for internal wiring and connecting wires in aerospace instruments, motor windings, and other fields.

Extreme temperatures cable USAGE SCOPE

TST-GH-S cold and heat resistant cable is Low Smoke Halogen Free Standard Wall Thickness Single Core with strong flame retardant. It has better fire resistance and shielding. This unit relates to power and control cables and their associated lines, which can reduce the hazard to people in case of fire and improve the safety of transportation. The insulation and sheath are made of halogen-free materials. In case of fire, this unit can limit the spread of flame, reduce the emission of toxic gases and smoke, reduce the loss of visibility, and enable personnel to evacuate quickly.

The highly flexible technology is specially designed to withstand extreme temperatures and is both flame retardant and resistant to temperatures as low as -60°C and complies with EN45545-2 fire rating HL3. This product has the characteristics of long-term high-temperature resistance, low-temperature resistance, radiation resistance, wear resistance, light weight, small size, and wide range. It is used for internal wiring and connecting wires in aerospace instruments, motor windings, and other fields.

 

Extreme temperatures cable Reference Standards

Comply with TJ/CL313-2014 Technical requirements for wires and cables of EMU

Pass BS6853:1999 and DIN5510-2:2009 Fireproof, smoke and toxicity testing

Comply with the requirements of internal and external cables of Class Ia, Ib and II locomotives in BS6853:1999

Comply with the requirements of flammability class S1~S5 in DIN5510-2:2009

 

Extreme temperatures cable Usage Features

  1. The rated AC voltage level: 600V
  2. Temperature resistance range: – 60~180 ℃
  3. Passed BS6853, DIN5510-2, EN45545-2 fire protection R15, R16 (HL3 level)
  4. Insulation strength: >100Mpa
  5. Sheath strength: >8Mpa
  6. Bending radius: fixed laying 5D; Non fixed laying 6D (D refers to the outer diameter of the cable)
  7. The cable meets the low-smoke and halogen-free performance. The gas release testing during cable combustion meets the requirements of total halogen gas < 5mg/g, pH value ≥ 4.3, conductivity≤10us/mm and light transmittance≥70%.
  8. Toxicity index: The equivalent European standard toxicity index shall not be greater than 3, and the equivalent TB standard toxicity index shall not be greater than 5.
  9. The cable can be used in the occasion polluted by mineral oil and fuel oil.
  10. The cable is resistant to single cable vertical burning.
  11. Solvent resistance, acid and alkali resistance.
  12. Cables can be produced in various colors according to customer requirements.

 

Cable structure DIAGRAM

no shield high cold and heat resistant single core cables TST-GH-S M -60~180℃ 600V

without sheath cable structure

A: Tinned copper annealed copper wire Class 5 conductor

B: Low smoke halogen-free polymer TST-101 insulation

 

high cold and heat resistant multi-core cables with shield  TST-GH-M MMS -60~180℃ 600V

multi-core with sheath structure

A: Tinned copper annealed copper wire Class 5 conductor

B: Low smoke halogen-free polymer TST-101 insulation

C: Tinned copper or silver-plated copper braid

D:Silicone rubber sheath

 

structure SIZE