Data cable Network cable

Data cable Network cable is mainly used for the internal network system of locomotives and for the transmission of a large amount of data to meet the needs of various vehicles’ internal control instruments, detection system images, sounds, and other transportation uses.

Reference Standards

TJ/CL313-2014
Code/T1019-2013
Article 568

Product Features

1. Impedance: 100 Ω
2. Conductor: Category 5 and Category 6 flexible conductors
Conductor material: bare copper, tin plated, silver plated
4. Bending radius 5D (special requirement)

Transmission characteristics

CAT5/5e CAT6 CAT6A CAT7
Impedance(Ω) 100±15

1~100MHz

100±15

1~250MHz

100±15  1~250MHz

100±22  150~500MHz

100±15  1~250MHz

100±22  150~500MHz

100±25  250~600MHz

Attenuation(dB/100m) <2.0   @1.0MHz

<21.3  @100MHz

<5.68  @1.0MHz

<49.27  @250MHz

<2.08  @1.0MHz

<45.26  @500MHz

<2.7  @1.0MHz

<75.5  @600MHz

Return loss(dB) >20.0  @1MHz

>19.0  @100MHz

>20.0  @1MHz

>17.3  @250MHz

>20.0  @1MHz

>17.3  @500MHz

>23.0  @4MHz

>15.6  @600MHz

Working capacitor ≤56PF/m  @1kHz ≤56nF/m @1kHz ≤56nF/km @1kHz ≤55nF/km @800Hz
Unbalanced capacitance to ground ≤1.6PF/m @1kHz ≤3.3PF/m @1kHz ≤160nF/km @1kHz ≤110nF/km @800Hz
Near-end crosstalk(dB) >62.3  @1MHz

>32.3  @100MHz

>74.3  @1MHz

>38.3  @250MHz

>75  @1MHz

>34.8  @500MHz

>75  @4MHz

>60.7  @600MHz

Test voltage 1000V DC 1min 1000V DC 1min 1000V DC 1min 1000V DC 1min
Scroll to Top