USAGE SCOPE
EN50264-3-1 cable is Low Smoke Halogen Free small-size wall-thick single core wire with strong flame retardant. It has better fire resistance and shielding. This unit relates to power and control cables and their associated lines, which can reduce the hazard to people in case of fire and improve the safety of transportation. The insulation and sheath are made of halogen-free materials. In case of fire, this unit can limit the spread of flame, reduce the emission of toxic gases and smoke, reduce the loss of visibility, and enable personnel to evacuate quickly.
Used as a power and control source in the internal or external installation of railway transport locomotives, handling and installation costs are important factors to consider in this environment. EN50264 power cables are used for control, auxiliary and main circuit wiring such as cable TV slings, switches and control panels, bridge, etc.
Reference Standards
Comply with TJ/CL313-2014 Technical requirements for wires and cables of EMU
Pass BS6853:1999 and DIN5510-2:2009 Fireproof, smoke and toxicity testing
Comply with the requirements of internal and external cables of Class Ia, Ib and II locomotives in BS6853:1999
Comply with the requirements of flammability class S1~S5 in DIN5510-2:2009
Usage Features
- The rated AC voltage level: 0.6/1kV, 1.8/3.0kV, 3.6/6.0kV
- Temperature resistance range: – 40~90 ℃, – 40~125 ℃
- Passed BS6853, DIN5510-2, EN45545-2 fire protection R15, R16 (HL3 level)
- Insulation strength: >10Mpa
- Elongation at break: >125%
- Bending radius: fixed laying 5D; Non fixed laying 6D (D refers to the outer diameter of the cable)
- The cable meets the low-smoke and halogen-free performance. The gas release testing during cable combustion meets the requirements of total halogen gas < 5mg/g, pH value ≥ 4.3, conductivity≤10us/mm and light transmittance≥70%.
- Toxicity index: The equivalent European standard toxicity index shall not be greater than 3, and the equivalent TB standard toxicity index shall not be greater than 5.
- The cable can be used in the occasion polluted by mineral oil and fuel oil.
- The cable is resistant to single cable vertical burning.
- Solvent resistance, acid and alkali resistance.
- Cables can be produced in various colors according to customer requirements.
Cable structure DIAGRAM
small-size wall-thick single core without sheath EN50264-3-1 0.6/1KV(1.8/3KV) M
A: Soft tinned annealed copper wire conductor
B: Standard low smoke halogen-free elastic compound insulation
small-size wall-thick single core with sheath EN50264-3-1 1.8/3KV(3.6/6KV) MM
A: Soft tinned annealed copper wire conductor
B: Standard low smoke halogen-free elastic compound insulation
C: Standard low smoke halogen-free elastic compound sheath
125℃ Fire-resistant cable TST-Z-FR EN50264-3-1 1.8/3KV(3.6/6KV) MM
A:Tinned copper conductor
B:Mica tape wrapping
C:Irradiation crosslinked polyolefin insulation
structure SIZE
small-size wall-thick single core without sheath EN50264-3-1 0.6/1KV M
Nominal section (mm²) |
Average thickness of insulation (MIN.mm) |
Outer diameter D (MIN.mm) |
Outer diameter D (MAX.mm) |
Reference weight (kg/km) |
1 | 0.6 | 2.4 | 2.8 | 17 |
1.5 | 0.7 | 2.8 | 3.3 | 23 |
2.5 | 0.7 | 3.2 | 3.8 | 32 |
4 | 0.7 | 3.8 | 4.4 | 48 |
6 | 0.7 | 4.2 | 5 | 67 |
10 | 0.7 | 5.1 | 5.9 | 107 |
16 | 0.7 | 6.1 | 7.2 | 160 |
25 | 0.9 | 7.8 | 9.1 | 248 |
35 | 0.9 | 9 | 10.6 | 339 |
50 | 1 | 10.6 | 12.4 | 482 |
70 | 1.1 | 12.5 | 14.6 | 673 |
95 | 1.1 | 13.9 | 16.3 | 875 |
120 | 1.2 | 15.7 | 18.4 | 1093 |
150 | 1.4 | 17.6 | 20.6 | 1377 |
185 | 1.6 | 19.6 | 22.9 | 1684 |
240 | 1.7 | 22.2 | 26 | 2172 |
small-size wall-thick single core without sheath EN50264-3-1 1.8/3.0KV M
Nominal section (mm²) |
Average thickness of insulation (MIN.mm) |
Outer diameter D (MIN.mm) |
Outer diameter D (MAX.mm) |
Reference weight (kg/km) |
1.5 | 2 | 5.3 | 6.2 | 51 |
2.5 | 2 | 5.7 | 6.7 | 65 |
4 | 2 | 6.2 | 7.3 | 86 |
6 | 2 | 6.7 | 7.8 | 109 |
10 | 2 | 7.5 | 8.8 | 154 |
16 | 2 | 8.6 | 10 | 221 |
25 | 2 | 9.9 | 11.6 | 304 |
35 | 2 | 11.1 | 13 | 410 |
50 | 2 | 12.5 | 14.6 | 541 |
70 | 2 | 14.2 | 16.6 | 733 |
95 | 2.2 | 16 | 18.7 | 966 |
120 | 2.2 | 17.6 | 20.6 | 1177 |
150 | 2.2 | 19.1 | 22.3 | 1450 |
185 | 2.4 | 20.9 | 24.4 | 1769 |
240 | 2.4 | 23.7 | 27.5 | 2253 |
small-size wall-thick single core with sheath EN50264-3-1 1.8/3KV MM
Nominal section (mm²) |
Average thickness of insulation (MIN.mm) |
Outer diameter D (MIN.mm) |
Outer diameter D (MAX.mm) |
Reference weight (kg/km) |
1.5 | 0.8 | 5.7 | 6.7 | 56 |
2.5 | 0.8 | 6 | 7 | 69 |
4 | 0.8 | 6.5 | 7.6 | 90 |
6 | 0.8 | 7 | 8.1 | 112 |
10 | 0.8 | 8.2 | 9.6 | 265 |
16 | 0.8 | 9.2 | 10.8 | 234 |
25 | 1 | 11.5 | 13.4 | 351 |
35 | 1 | 12.7 | 14.9 | 453 |
50 | 1 | 14.1 | 16.5 | 606 |
70 | 1 | 15.8 | 18.5 | 809 |
95 | 1 | 18 | 21 | 1061 |
120 | 1 | 19.6 | 22.9 | 1277 |
150 | 1.2 | 21.4 | 25.1 | 1589 |
185 | 1.2 | 23.4 | 27.4 | 1922 |
240 | 1.2 | 25.9 | 30.4 | 2421 |
small-size wall-thick single core with sheath EN50264-3-1 3.6/6.0KV MM
Nominal section (mm²) |
Average thickness of insulation (MIN.mm) |
Outer diameter D (MIN.mm) |
Outer diameter D (MAX.mm) |
Reference weight (kg/km) |
2.5 | 2.6 | 8.6 | 10.1 | 130 |
4 | 2.6 | 9.1 | 10.7 | 155 |
6 | 2.6 | 9.6 | 11.2 | 183 |
10 | 2.6 | 10.4 | 12.2 | 236 |
16 | 2.6 | 11.5 | 13.4 | 315 |
25 | 2.9 | 13.7 | 16.1 | 447 |
35 | 2.9 | 14.9 | 17.5 | 556 |
50 | 2.9 | 16.4 | 19.1 | 717 |
70 | 2.9 | 18 | 21.1 | 925 |
95 | 2.9 | 19.5 | 22.8 | 1158 |
120 | 2.9 | 21.4 | 25.1 | 1412 |
150 | 2.9 | 22.9 | 26.8 | 1702 |
185 | 3.2 | 25.1 | 29.4 | 2068 |
240 | 3.4 | 28.3 | 33.1 | 2635 |