EN50264-3-2 cable small-size wall-thick multi-core

EN50264-3-2 cable is low smoke halogen free, small-size wall-thick multi-core power cable, including with shield and without shield two types. It has better fire resistance and shielding, passed the CRCC certification and EN45545-2 fire test. Suitable for power supply, control panel, and electrical cabinet in various compartments.

EN50264-3-2 cable USAGE SCOPE

EN50264-3-2 cable is Low Smoke Halogen Free small-size wall-thick multi-core with strong flame retardant. It has better fire resistance and shielding. This unit relates to power and control cables and their associated lines, which can reduce the hazard to people in case of fire and improve the safety of transportation. The insulation and sheath are made of halogen-free materials. In case of fire, this unit can limit the spread of flame, reduce the emission of toxic gases and smoke, reduce the loss of visibility, and enable personnel to evacuate quickly.

Used as a power and control source in the internal or external installation of railway transport locomotives, handling and installation costs are important factors to consider in this environment. EN50264 power cables are used for control, auxiliary and main circuit wiring such as cable TV slings, switches and control panels, bridge, etc.

 

EN50264-3-2 cable Reference Standards

Comply with TJ/CL313-2014 Technical requirements for wires and cables of EMU

Pass BS6853:1999 and DIN5510-2:2009 Fireproof, smoke and toxicity testing

Comply with the requirements of internal and external cables of Class Ia, Ib and II locomotives in BS6853:1999

Comply with the requirements of flammability class S1~S5 in DIN5510-2:2009

 

EN50264-3-2 cable Usage Features

  1. The rated AC voltage level: 300/500V, 0.6/1kV
  2. Temperature resistance range: – 40~90 ℃
  3. Passed BS6853, DIN5510-2, EN45545-2 fire protection R15, R16 (HL3 level)
  4. Insulation strength: >10Mpa
  5. Elongation at break: >125%
  6. Bending radius: fixed laying 5D; Non fixed laying 6D (D refers to the outer diameter of the cable)
  7. The cable meets the low-smoke and halogen-free performance. The gas release testing during cable combustion meets the requirements of total halogen gas < 5mg/g, pH value ≥ 4.3, conductivity≤10us/mm and light transmittance≥70%.
  8. Toxicity index: The equivalent European standard toxicity index shall not be greater than 3, and the equivalent TB standard toxicity index shall not be greater than 5.
  9. The cable can be used in the occasion polluted by mineral oil and fuel oil.
  10. The cable is resistant to single cable vertical burning.
  11. Solvent resistance, acid and alkali resistance.
  12. Cables can be produced in various colors according to customer requirements.

 

EN50264-3-2 cable structure DIAGRAM

small-size wall-thick multi-core cable without shield EN50264-3-2 300/500V MM

EN50264-3-2 without shield Cable structure diagram

A: Soft tinned annealed copper wire conductor

B: Standard low smoke halogen-free elastic compound insulation

C: Standard low smoke halogen-free elastic compound sheath

 

small-size wall-thick multi-core cable with shield EN50264-3-2 300/500V (0.6/1.0kV) MMS

EN50264-3-2 cable with shield

A: Soft tinned annealed copper wire conductor

B: Standard low smoke halogen-free elastic compound insulation

C:Tinned annealed copper braid shielding

D: Standard low smoke halogen-free elastic compound sheath

 

Scroll to Top