EN50382 silicone rubber cable USAGE SCOPE
EN50382 silicone rubber cable is Low Smoke Halogen Free Standard Wall Thickness Single Core with strong flame retardant. It has better fire resistance and shielding. This unit relates to power and control cables and their associated lines, which can reduce the hazard to people in case of fire and improve the safety of transportation. The insulation and sheath are made of halogen-free materials. In case of fire, this unit can limit the spread of flame, reduce the emission of toxic gases and smoke, reduce the loss of visibility, and enable personnel to evacuate quickly.
EN50382 silicone rubber cable Especially suitable for large cross-section single core and multi core power cables. Silicon wires are mainly used for electrical connections between high-temperature electrical equipment such as power generation, metallurgy, and chemical engineering.
EN50382 silicone rubber cable Reference Standards
Comply with TJ/CL313-2014 Technical requirements for wires and cables of EMU
Pass BS6853:1999 and DIN5510-2:2009 Fireproof, smoke and toxicity testing
Comply with the requirements of internal and external cables of Class Ia, Ib and II locomotives in BS6853:1999
Comply with the requirements of flammability class S1~S5 in DIN5510-2:2009
EN50382 silicone rubber cable Usage Features
- The rated AC voltage level: 1.8/3.0kV, 3.6/6.0kV
- Temperature resistance range: – 50~120 ℃, – 50~150 ℃
- Passed BS6853, DIN5510-2, EN45545-2 fire protection R15, R16 (HL3 level)
- Insulation strength: >8Mpa
- Elongation at break: >200%
- Bending radius: fixed laying 5D; Non fixed laying 6D (D refers to the outer diameter of the cable)
- The cable meets the low-smoke and halogen-free performance. The gas release testing during cable combustion meets the requirements of total halogen gas < 5mg/g, pH value ≥ 4.3, conductivity≤10us/mm and light transmittance≥70%.
- Toxicity index: The equivalent European standard toxicity index shall not be greater than 3, and the equivalent TB standard toxicity index shall not be greater than 5.
- The cable can be used in the occasion polluted by mineral oil and fuel oil.
- The cable is resistant to single cable vertical burning.
- Solvent resistance, acid and alkali resistance.
- Cables can be produced in various colors according to customer requirements.
EN50382 silicone rubber cable structure DIAGRAM
1.8/3.0kV no sheath silicone rubber cable(120℃) M
1.8/3.0kV no sheath silicone rubber cable(150℃) M
3.6/6.0kV no sheath silicone rubber cable(120℃) M
3.6/6.0kV no sheath silicone rubber cable(150℃) M
A: Tinned copper annealed copper wire Class 5 conductor
B: Silicone rubber insulation
1.8/3.0kV silicone rubber cable(120℃) with sheath M
1.8/3.0kV silicone rubber cable(150℃) with sheath M
3.6/6.0kV silicone rubber cable(120℃) with sheath M
3.6/6.0kV silicone rubber cable(150℃) with sheath M
A: Tinned copper annealed copper wire Class 5 conductor
B: Silicone rubber insulation
C: Silicone rubber insulation sheath