REFERENCE STANDARD
IEC62893
EN50260
UL62
GB/T33594
CQC1103-1105
PRODUCT CHARACTERISTICS
1. Rated voltage: AC 450/750V, DC 1.0KV
2. Section square: 0.75mm2, 1.5mm2, 2.5mm2, 4.0mm2, 6.0mm2, 16mm2, 20mm2, 35mm2, 50mm2, 80mm2
3. Number of cable cores: signal line + control line + power line
4. Conductor: Class 5 and Class 6 soft conductors
5. Bending radius 5D (special requirements)
MATERIAL PROPERTIES
Insulation And Sheathing Materials | |||||
sulation Materials (Elastomer material) |
Sheath material (Elastomer material) |
Temperature ℃ | |||
Conductor allowable temperature | Cable surface | Installation and laying | |||
Long | Short circuit | ||||
Highest | Highest | Highest | Lowest | ||
S | S | +70 | +200 | +50 | -25 |
S90 | U | +90 | +250 | +75 | -40 |
E | U | +90 | +250 | +75 | -40 |
E1 | U1 | +90 | +250 | +75 | -40 |
E1 | YJ1 | +90 | +250 | +75 | -40 |