Photoelectric speed sensor cable Rail transit cable

Photoelectric speed sensor cable is Low Smoke Halogen Free with strong flame retardant. It’s a special cable for rail vehicles. The cable has a small outer diameter and high strength and is suitable for suspended installation.

Photoelectric speed sensor cable USAGE SCOPE

Photoelectric speed sensor cable WDZ-DC-B-ZP-HRR-125 is Low Smoke Halogen Free with strong flame retardant. It has better fire resistance and shielding. This unit relates to power and control cables and their associated lines, which can reduce the hazard to people in case of fire and improve the safety of transportation. The insulation and sheath are made of halogen-free materials. In case of fire, this unit can limit the spread of flame, reduce the emission of toxic gases and smoke, reduce the loss of visibility, and enable personnel to evacuate quickly.

Photoelectric speed sensor cable WDZ-DC-B-ZP-HRR-125 has a small outer diameter and high strength and is suitable for suspended installation.

 

Photoelectric speed sensor cable Reference Standards

Comply with TJ/CL313-2014 Technical requirements for wires and cables of EMU

Pass BS6853:1999 and DIN5510-2:2009 Fireproof, smoke and toxicity testing

Comply with the requirements of internal and external cables of Class Ia, Ib and II locomotives in BS6853:1999

Comply with the requirements of flammability class S1~S5 in DIN5510-2:2009

 

Photoelectric speed sensor cable Usage Features

  1. The rated AC voltage level: 750V (Test voltage 4000V/5min)
  2. Temperature resistance range: – 40~125℃
  3. Passed BS6853, DIN5510-2, EN45545-2 fire protection R15, R16 (HL3 level)
  4. Insulation strength: >12Mpa
  5. Elongation at break: >125%
  6. Bending radius: fixed laying 5D; Non fixed laying 6D (D refers to the outer diameter of the cable)
  7. The cable meets the low-smoke and halogen-free performance. The gas release testing during cable combustion meets the requirements of total halogen gas < 5mg/g, pH value ≥ 4.3, conductivity≤10us/mm and light transmittance≥70%.
  8. Toxicity index: The equivalent European standard toxicity index shall not be greater than 3, and the equivalent TB standard toxicity index shall not be greater than 5.
  9. The cable can be used in the occasion polluted by mineral oil and fuel oil.
  10. The cable is resistant to single cable vertical burning.
  11. Solvent resistance, acid and alkali resistance.
  12. Cables can be produced in various colors according to customer requirements.

 

Photoelectric speed sensor cable structure DIAGRAM

Photoelectric speed sensor cable WDZ-DC-B-ZP-HRR-125 750V

Photoelectric speed sensor cable structure diagram

 

Scroll to Top