TST-9AX 3600V Cable series

The low-smoke halogen-free compact cable TST-9AX 3600V M is a compact, flexible multi-core or single core cable with a small diameter and light weight to meet the requirements of current rail transit cables. Halogen-free, flame retardant, low smoke and low toxicity index, while meeting the requirements of wear resistance, ozone resistance and oil resistance. It is suitable for fixed and moving parts connected inside and outside the locomotive and vehicle DC and AC occasions, especially suitable for inverter technology occasions.

 

 

Reference Standards

Comply with TJ/CL313-2014 Technical requirements for wires and cables of EMU

Pass BS6853:1999 and DIN5510-2:2009 Fireproof, smoke and toxicity testing

Comply with the requirements of internal and external cables of Class Ia, Ib and II locomotives in BS6853:1999

Comply with the requirements of flammability class S1~S5 in DIN5510-2:2009

EN45545 European fire rating standard

 

Usage Features

  1. The rated AC voltage level: 3600V
  2. Temperature resistance range: -40~105℃
  3. Passed BS6853, DIN5510-2, EN45545-2 fire protection R15, R16 (HL3 level)
  4. Insulation strength: >10Mpa
  5. Elongation at break: >125%
  6. Bending radius: 6D (D refers to the outer diameter of the cable)
  7. The cable meets the low-smoke and halogen-free performance. The gas release testing during cable combustion meets the requirements of total halogen gas < 5mg/g, pH value ≥ 4.3, conductivity≤10us/mm and light transmittance≥70%.
  8. Toxicity index: The equivalent European standard toxicity index shall not be greater than 3, and the equivalent TB standard toxicity index shall not be greater than 5.
  9. The cable can be used in the occasion polluted by mineral oil and fuel oil.
  10. The cable is resistant to single cable vertical burning.
  11. Solvent resistance, acid and alkali resistance.
  12. Cables can be produced in various colors according to customer requirements.

 

Cable structure DIAGRAM

TST-9AX 3600V MMS Single core with shield cable series

TST-9AX 3600V MMS multi-core with shield cable series

TST-9AX cable structure

A: Tinned copper annealed copper wire Category 5 or Category 6 conductors

B: Irradiation crosslinked polyolefin insulation

C: Tinned copper braid shielding

D:Irradiated cross-linked polyolefin or rubber elastomers sheath

 

TST-9AX 3600V M single core without shield cable series

no sheath

A: Tinned copper annealed copper wire Category 5 conductors

B: Irradiation crosslinked polyolefin insulation

 

structure SIZE

TST-9AX 3600V MMS Single core with shield cable series

Nominal section of conductor
(mm²)
Thickness of insulation
(MIN.mm)
Outer diameter D
(MIN.mm)
Outer diameter D
(MAX.mm)
Reference weight
(kg/km)
1.5 1.52 6.4 6.8 74
2.5 1.95 7 7.4 96
4 2.4 8 8.4 121
6 2.95 8.9 9.3 155
10 3.9 10.2 10.6 221
16 5.3 12.1 12.7 348
25 6.6 14 14.6 426.5
35 7.8 15.4 16 557.8
50 9.3 17.4 18 732
70 11.4 19.7 20.3 1012
95 12.9 21.7 22.3 1257
120 14.9 24.3 25 1588
150 16.8 26.8 27.4 1962
185 18.3 29.4 25.3 2248
240 21.1 32.5 28.3 2892

 

TST-9AX 3600V M single core without shield cable series

Nominal section of conductor
(mm²)
Average thickness of insulation
(MIN.mm)
Outer diameter D
(MIN.mm)
Outer diameter D
(MAX.mm)
Reference weight
(kg/km)
1.5 3 4.4 4.6 34
2.5 3 5 5.2 48
4 3 5.6 5.8 67
6 3 6.2 6.4 86.8
10 3.5 7.35 7.65 139.8
16 4 9.15 9.65 209.3
25 4 10.7 11.3 301.1
35 4.5 12.3 12.9 423.6
50 5 14.3 14.9 581.3
70 5 16.4 17 802.1
95 5.5 18.4 19 1018
120 5.5 20.7 21.3 1283
150 6 22.9 23.5 1613
185 6.5 24.7 25.3 1897
240 2.1 27.7 28.3 2436

 

TST-9AX 3600V MMS multi-core with shield cable series

Number of cores×Nominal section of conductor
(mm²)
Average thickness of insulation
(MIN.mm)
Outer diameter D
(MIN.mm)
Outer diameter D
(MAX.mm)
Reference weight
(kg/km)
3×4.0 1.6 16 17 181
6×4.0 1.6 22.3 23.3 342
4×6.0 1.6 20.3 21.3 317
2×10 1.8 19..2 20.2 283
4×35 2.4 39 40.4 1583

 

Scroll to Top