Reference Standards
Comply with TJ/CL313-2014 Technical requirements for wires and cables of EMU
Pass BS6853:1999 and DIN5510-2:2009 Fireproof, smoke and toxicity testing
Comply with the requirements of internal and external cables of Class Ia, Ib and II locomotives in BS6853:1999
Comply with the requirements of flammability class S1~S5 in DIN5510-2:2009
EN45545 European fire rating standard
Usage Features
- The rated AC voltage level: 3600V
- Temperature resistance range: -40~105℃
- Passed BS6853, DIN5510-2, EN45545-2 fire protection R15, R16 (HL3 level)
- Insulation strength: >10Mpa
- Elongation at break: >125%
- Bending radius: 6D (D refers to the outer diameter of the cable)
- The cable meets the low-smoke and halogen-free performance. The gas release testing during cable combustion meets the requirements of total halogen gas < 5mg/g, pH value ≥ 4.3, conductivity≤10us/mm and light transmittance≥70%.
- Toxicity index: The equivalent European standard toxicity index shall not be greater than 3, and the equivalent TB standard toxicity index shall not be greater than 5.
- The cable can be used in the occasion polluted by mineral oil and fuel oil.
- The cable is resistant to single cable vertical burning.
- Solvent resistance, acid and alkali resistance.
- Cables can be produced in various colors according to customer requirements.
Cable structure DIAGRAM
TST-9AX 3600V MMS Single core with shield cable series
TST-9AX 3600V MMS multi-core with shield cable series
A: Tinned copper annealed copper wire Category 5 or Category 6 conductors
B: Irradiation crosslinked polyolefin insulation
C: Tinned copper braid shielding
D:Irradiated cross-linked polyolefin or rubber elastomers sheath
TST-9AX 3600V M single core without shield cable series
A: Tinned copper annealed copper wire Category 5 conductors
B: Irradiation crosslinked polyolefin insulation
structure SIZE
TST-9AX 3600V MMS Single core with shield cable series
Nominal section of conductor (mm²) |
Thickness of insulation (MIN.mm) |
Outer diameter D (MIN.mm) |
Outer diameter D (MAX.mm) |
Reference weight (kg/km) |
1.5 | 1.52 | 6.4 | 6.8 | 74 |
2.5 | 1.95 | 7 | 7.4 | 96 |
4 | 2.4 | 8 | 8.4 | 121 |
6 | 2.95 | 8.9 | 9.3 | 155 |
10 | 3.9 | 10.2 | 10.6 | 221 |
16 | 5.3 | 12.1 | 12.7 | 348 |
25 | 6.6 | 14 | 14.6 | 426.5 |
35 | 7.8 | 15.4 | 16 | 557.8 |
50 | 9.3 | 17.4 | 18 | 732 |
70 | 11.4 | 19.7 | 20.3 | 1012 |
95 | 12.9 | 21.7 | 22.3 | 1257 |
120 | 14.9 | 24.3 | 25 | 1588 |
150 | 16.8 | 26.8 | 27.4 | 1962 |
185 | 18.3 | 29.4 | 25.3 | 2248 |
240 | 21.1 | 32.5 | 28.3 | 2892 |
TST-9AX 3600V M single core without shield cable series
Nominal section of conductor (mm²) |
Average thickness of insulation (MIN.mm) |
Outer diameter D (MIN.mm) |
Outer diameter D (MAX.mm) |
Reference weight (kg/km) |
1.5 | 3 | 4.4 | 4.6 | 34 |
2.5 | 3 | 5 | 5.2 | 48 |
4 | 3 | 5.6 | 5.8 | 67 |
6 | 3 | 6.2 | 6.4 | 86.8 |
10 | 3.5 | 7.35 | 7.65 | 139.8 |
16 | 4 | 9.15 | 9.65 | 209.3 |
25 | 4 | 10.7 | 11.3 | 301.1 |
35 | 4.5 | 12.3 | 12.9 | 423.6 |
50 | 5 | 14.3 | 14.9 | 581.3 |
70 | 5 | 16.4 | 17 | 802.1 |
95 | 5.5 | 18.4 | 19 | 1018 |
120 | 5.5 | 20.7 | 21.3 | 1283 |
150 | 6 | 22.9 | 23.5 | 1613 |
185 | 6.5 | 24.7 | 25.3 | 1897 |
240 | 2.1 | 27.7 | 28.3 | 2436 |
TST-9AX 3600V MMS multi-core with shield cable series
Number of cores×Nominal section of conductor (mm²) |
Average thickness of insulation (MIN.mm) |
Outer diameter D (MIN.mm) |
Outer diameter D (MAX.mm) |
Reference weight (kg/km) |
3×4.0 | 1.6 | 16 | 17 | 181 |
6×4.0 | 1.6 | 22.3 | 23.3 | 342 |
4×6.0 | 1.6 | 20.3 | 21.3 | 317 |
2×10 | 1.8 | 19..2 | 20.2 | 283 |
4×35 | 2.4 | 39 | 40.4 | 1583 |