WTB data cable USAGE SCOPE
WTB data cable is based on the fireproof performance requirements of the rail transit industry. Under the fire, the smoke is very small when the cable burns, and the smoke is not toxic and corrosive and does not cause secondary combustion. The cable has good EMC characteristics and is used for multifunctional data transmission in vehicles.
WTB data cable Reference Standards
Comply with TJ/CL313-2014 Technical requirements for wires and cables of EMU
Pass BS6853:1999 and DIN5510-2:2009 Fireproof, smoke and toxicity testing
Comply with the requirements of internal and external cables of Class Ia, Ib and II locomotives in BS6853:1999
Comply with the requirements of flammability class S1~S5 in DIN5510-2:2009
TB/T1484.4 Rolling stock: Low-smoke halogen-free flame
retardant cables for communications and network
EN45545 European fire rating standard
WTB data cable Usage Features
- The rated AC voltage level: 300V AC
- Temperature resistance range: – 40~90 ℃
- Attenuation: <1.0dB/100m(1MHZ)/ <1.4dB/100m(2MHZ)
- Characteristic impedance: 120Ω±12Ω(0.5~2MHZ)
- Transfer impedance: <20mΩ/m(20MHZ)
- Bending radius: 6D (D refers to the outer diameter of the cable)
- Operating capacitance: ≤65PF/M(1.0MHZ)
- Ground capacitance: ≤1.5PF/M(1.0MHZ)
- Toxicity index: The equivalent European standard toxicity index shall not be greater than 3, and the equivalent TB standard toxicity index shall not be greater than 5.
- The cable can be used in the occasion polluted by mineral oil and fuel oil.
- The cable is resistant to single cable vertical burning.
- Solvent resistance, acid and alkali resistance.
WTB data cable structure DIAGRAM
Cable size
Number of cores×Nominal section (n×mm²) |
Conductor diameter (mm²) | External diameter of insulation (mm²) | Outer diameter of cable (mm²) |
2×0.5 | 0.9 | 2.2 | 7.9 |
2×0.75 | 1.15 | 3.7 | 9.3 |