EN50306-2 electric cable Thin wall single core

EN50306-2 electric cable is low-smoke, halogen-free, Thin wall single core and flame-retardant. This cable has a smaller outer diameter, lighter weight and better flexibility. It is suitable for various signal transmission control wiring.

USAGE SCOPE

EN50306-2 electric cable is Low Smoke Halogen Free Thin wall single core with strong flame retardant. It has better fire resistance and shielding. This unit relates to power and control cables and their associated lines, which can reduce the hazard to people in case of fire and improve the safety of transportation. The insulation and sheath are made of halogen-free materials. In case of fire, this unit can limit the spread of flame, reduce the emission of toxic gases and smoke, reduce the loss of visibility, and enable personnel to evacuate quickly.

The new EN50306 railway cable is based on the newly developed halogen-free electron beam crosslinked insulation system EI 306 and sheathing materials, and meets the specifications of standard EN50306 cables. The cable is suitable for fixed wiring of vehicles, as well as slightly flexible wiring and electrical energy transmission. EN50306 is suitable for miniaturized wire and cable of vehicle equipment electrical device.

 

Reference Standards

Comply with TJ/CL313-2014 Technical requirements for wires and cables of EMU

Pass BS6853:1999 and DIN5510-2:2009 Fireproof, smoke and toxicity testing

Comply with the requirements of internal and external cables of Class Ia, Ib and II locomotives in BS6853:1999

Comply with the requirements of flammability class S1~S5 in DIN5510-2:2009

 

Usage Features

  1. The rated AC voltage level: 300V, 600V
  2. Temperature resistance range: – 40~105 ℃
  3. The outer diameter of the cable is smaller and the weight is lighter.  The cable adopts single-layer insulation structure or double-layer insulation structure.
  4. Passed BS6853, DIN5510-2, EN45545-2 fire protection R15, R16 (HL3 level)
  5. Insulation strength: >10Mpa
  6. Elongation at break: >125%
  7. Bending radius: fixed laying 4D; Non fixed laying 6D (D refers to the outer diameter of the cable)
  8. The cable meets the low-smoke and halogen-free performance. The gas release testing during cable combustion meets the requirements of total halogen gas < 5mg/g, pH value ≥ 4.3, conductivity≤10us/mm and light transmittance≥80%.
  9. Toxicity index: The equivalent European standard toxicity index shall not be greater than 3, and the equivalent TB standard toxicity index shall not be greater than 5.
  10. The cable can be used in the occasion polluted by mineral oil and fuel oil.
  11. The cable is resistant to single cable vertical burning.
  12. Solvent resistance, acid and alkali resistance.
  13. Cables can be produced in various colors according to customer requirements.

 

Cable structure DIAGRAM

Thin wall single core cable EN50306-2 300V M

EN50306-2 single core cable

A: Soft tinned annealed copper wire conductor

B: Standard low smoke halogen-free elastic compound insulation

 

STRUCTURE SIZE

Thin wall single core cable EN50306-2 300V M

Nominal section of conductor
(mm²)
Average thickness of insulation
(MIN.mm)
Outer diameter D
(MIN.mm)
Outer diameter D
(MAX.mm)
Reference weight
(kg/km)
0.5 0.18 1.15 1.45 5.9
0.75 0.18 1.35 1.65 8.1
1 0.18 1.45 1.8 10.1
1.5 0.22 1.95 2.3 16.5
2.5 0.28 2.5 2.85 27.5

 

Scroll to Top