200℃ Low Weight High Temperature Single Core Cable TST-LW 600V M

200℃ Low Weight High Temperature Cable TST-LW 600V M is a new generation of control signal cable, which is specially developed for railway vehicles, does not contain halogen, does not release any corrosive gas in case of fire, has flame retardant, does not spread fire, low smoke halogen free, low toxicity index; Smaller, lighter and more flexible. As a thin-wall cable, it is particularly suitable for the wiring of control panels and electric control boxes, carriage wiring, terminal boxes, power supplies of various systems and ground connections in railway vehicles with mobile devices. Meets the requirements of European railway fire protection standards.

Reference Standards

Comply with TJ/CL313-2014 Technical requirements for wires and cables of EMU

Pass BS6853:1999 and DIN5510-2:2009 Fireproof, smoke and toxicity testing

Comply with the requirements of internal and external cables of Class Ia, Ib and II locomotives in BS6853:1999

Comply with the requirements of flammability class S1~S5 in DIN5510-2:2009

EN45545 European fire rating standard

 

Usage Features

  1. The rated AC voltage level: 600V
  2. Temperature resistance range: – 50~200 ℃, – 50~125 ℃
  3. Passed BS6853, DIN5510-2, EN45545-2 fire protection R15, R16 (HL3 level)
  4. Insulation strength: >10Mpa
  5. Elongation at break: >125%
  6. Non fixed laying 6D (D refers to the outer diameter of the cable)
  7. The cable meets the low-smoke and halogen-free performance. The gas release testing during cable combustion meets the requirements of total halogen gas < 5mg/g, pH value ≥ 4.3, conductivity≤10us/mm and light transmittance≥70%.
  8. Toxicity index: The equivalent European standard toxicity index shall not be greater than 3, and the equivalent TB standard toxicity index shall not be greater than 5.
  9. The cable can be used in the occasion polluted by mineral oil and fuel oil.
  10. The cable is resistant to single cable vertical burning.
  11. Solvent resistance, acid and alkali resistance.
  12. Cables can be produced in various colors according to customer requirements.

 

Cable structure DIAGRAM

200℃ Low Weight High Temperature Single Core Cable TST-LW 600V M

TST-LW cable structure

A: Tinned copper annealed copper wire Class 5 conductor

B: Standard low smoke halogen-free elastic compound insulation

 

125℃ Low Weight Cable TST-TW 600V MM

A:Tinned copper annealed copper wire Category 5 conductors

B:Standard low smoke halogen-free elastic compound insulation

C:Standard low smoke halogen-free elastic compound sheath

 

structure SIZE

200℃ Low Weight High Temperature Single Core Cable TST-LW 600V M

Nominal section of conductor
(mm²)
Average thickness of insulation
(MIN.mm)
Outer diameter D
(MIN.mm)
Outer diameter D
(MAX.mm)
Reference weight
(kg/km)
0.5 0.18 1.15 1.45 5.9
0.75 0.18 1.35 1.65 8.1
1 0.18 1.45 1.8 10.1
1.5 0.22 1.95 2.3 16.5
2.5 0.28 2.5 2.85 27.5

 

125℃ Low Weight Cable TST-TW 600V MM

Nominal section of conductor
(mm²)
Average thickness of insulation
(MIN.mm)
Outer diameter D
(MIN.mm)
Outer diameter D
(MAX.mm)
Reference weight
(kg/km)
0.5 0.18 1.2 1.35 5.3
0.75 0.18 1.4 1.55 7.8
1 0.18 1.5 1.7 9.7
1.5 0.22 1.85 2.05 15.4
2.5 0.28 2.25 2.55 25.4

 

 

Scroll to Top