LSOH Temperature sensor cable 200℃ flame retardant

Temperature sensor cable is Low Smoke Halogen Free with strong flame retardant. Cable produce very little smoke in the case of flame combustion, and the released gas does not contain halogen elements, is non-toxic, and meets the European fire protection standard of EN45545-2. Widely used in high-rise buildings, hospitals, large libraries, gymnasiums, disaster prevention command and dispatch buildings.

USAGE SCOPE

Temperature sensor cable WDZ-DC-B-ZP-H-DYT-125(200) is Low Smoke Halogen Free Standard Wall Thickness Single Core with strong flame retardant. It has better fire resistance and shielding. This unit relates to power and control cables and their associated lines, which can reduce the hazard to people in case of fire and improve the safety of transportation. The insulation and sheath are made of halogen-free materials. In case of fire, this unit can limit the spread of flame, reduce the emission of toxic gases and smoke, reduce the loss of visibility, and enable personnel to evacuate quickly.

The temperature sensor cable is widely used in high-rise buildings, hospitals, large libraries, gymnasiums, disaster prevention command and dispatch buildings, stations and civil airports, passenger waiting rooms, key cultural relics protection sites, and subways, underground shopping malls or densely populated public places.

 

Reference Standards

Comply with TJ/CL313-2014 Technical requirements for wires and cables of EMU

Pass BS6853:1999 and DIN5510-2:2009 Fireproof, smoke and toxicity testing

Comply with the requirements of internal and external cables of Class Ia, Ib and II locomotives in BS6853:1999

Comply with the requirements of flammability class S1~S5 in DIN5510-2:2009

 

Usage Features

  1. The rated AC voltage level: 750V
  2. Temperature resistance range: – 40℃~(insulation core 200℃, sheath 125℃)
  3. Passed BS6853, DIN5510-2, EN45545-2 fire protection R15, R16 (HL3 level)
  4. Insulation strength: >100Mpa
  5. Elongation at break: >125%
  6. Bending radius: fixed laying 5D; Non fixed laying 6D (D refers to the outer diameter of the cable)
  7. The cable meets the low-smoke and halogen-free performance. The gas release testing during cable combustion meets the requirements of total halogen gas < 5mg/g, pH value ≥ 4.3, conductivity≤10us/mm and light transmittance≥70%.
  8. Toxicity index: The equivalent European standard toxicity index shall not be greater than 3, and the equivalent TB standard toxicity index shall not be greater than 5.
  9. The cable can be used in the occasion polluted by mineral oil and fuel oil.
  10. The cable is resistant to single cable vertical burning.
  11. Solvent resistance, acid and alkali resistance.
  12. Cables can be produced in various colors according to customer requirements.

 

Cable structure DIAGRAM

Low smoke halogen-free flame retardant temperature sensor cable WDZ-DC-B-ZP-H-DYT-125(200)

temperature sensor cable structure

 

 